dc.description.abstract | An experimental study was conducted in a laboratory scale model in order to characterize the airflow generated by an air curtain device (ACD) on the aerodynamic sealing of refrigerated spaces. The laboratory scale model consists of two similar adjacent rooms connected by a door over which the ACD device was installed. The tracer gas technique was used to calculate the sealing effect achieved with the air curtain at different jet velocities. A three-dimensional numerical model was also developed to simulate the heat and mass transfer phenomena, as well as the aerodynamic sealing performance of an ACD. The numerical study was carried out using a commercial CFD code (ANSYS-CFX®) and the turbulence effects were approached by two different turbulence models (k–ε and k–ω SST). The experimental and numerical results show a good agreement for validation purposes. No significant differences were found in the results obtained with the two turbulence models, although the k–ω SST model seems to be more appropriate for the simulations. The existence of an optimum discharge air jet velocity was confirmed. The results also indicate that the air curtain is more efficient in reducing the mass transfer than the energy flow rate across the doorway. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Gonçalves, J.C., Costa, J.J., Figueiredo, A.R., & Lopes, A.M.G. (2012). Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches. Energy and Buildings, 55, 779-789. doi:10.1016/j.enbuild.2012.10.021 | pt_PT |
dc.identifier.doi | 10.1016/j.enbuild.2012.10.021 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10400.19/6124 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Energy and Buildings | pt_PT |
dc.relation.publisherversion | https://doi.org/10.1016/j.enbuild.2012.10.021 | pt_PT |
dc.subject | Air curtain | pt_PT |
dc.subject | Refrigerated room | pt_PT |
dc.subject | Sealing efficiency | pt_PT |
dc.subject | Heat transfer | pt_PT |
dc.subject | CFD | pt_PT |
dc.subject | Energy saving | pt_PT |
dc.title | Study of the aerodynamic sealing of a cold store – Experimental and numerical approaches | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 789 | pt_PT |
oaire.citation.startPage | 779 | pt_PT |
oaire.citation.title | Energy and Buildings | pt_PT |
oaire.citation.volume | 55 | pt_PT |
person.familyName | Gonçalves | |
person.givenName | João Carlos | |
person.identifier | 1299655 | |
person.identifier.ciencia-id | E411-A4A3-F728 | |
person.identifier.orcid | 0000-0003-3763-1503 | |
person.identifier.scopus-author-id | 55951854100 | |
rcaap.rights | closedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 397e6196-5fed-44bb-b807-dacd9b85ae27 | |
relation.isAuthorOfPublication.latestForDiscovery | 397e6196-5fed-44bb-b807-dacd9b85ae27 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Study of the aerodynamic sealing of a cold store -Artigo JCG 2012_Abstract.pdf
- Size:
- 337 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.79 KB
- Format:
- Item-specific license agreed upon to submission
- Description: