Repository logo
 
Publication

A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings

dc.contributor.authorAlmeida, Ricardo
dc.contributor.authorRamos, Nuno M.M.
dc.contributor.authorPereira, Pedro F.
dc.date.accessioned2017-01-23T10:02:13Z
dc.date.available2017-01-23T10:02:13Z
dc.date.issued2017
dc.description.abstractAdequate airtightness levels are fundamental for the indoor environmental quality and energy efficiency of buildings. The quantitative characterization of expected leaks of common building elements is useful for practitioners that intend to improve building enclosures for airtightness optimization. This study intends to contribute to the quantification of the permeability of windows with a focus on the Southern European context of low airtightness in heavy construction buildings, where windows play an important role. A large experimental investigation was therefore carried out in 23 spaces, establishing three possible set-ups (nothing sealed, window sealed and window and roller-shutter sealed), using the fan pressurization method. A total of 104 tests were performed. Results revealed that the windows’ permeability indices ranged from 4.8 to 96.4 m3/(h m2) and from 1.2 to 30.8 m3/(h m), with average values of 28.7 m3/(h m2) and 8.9 m3/(h m), the roller-shutter contribution can be highly variable; also the year of construction, the frame material and the opening system are the key parameters for the airtightness of windowspt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationAlmeida, R. M. S. F., Ramos, N. M. M., & Pereira, P. F. (2017). A contribution for the quantification of the influence of windows on the airtightness of Southern European buildings. Energy and Buildings, 139, 174–185.pt_PT
dc.identifier.doi10.1016/j.enbuild.2017.01.012pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.19/4076
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0378778817300543pt_PT
dc.subjectWindowspt_PT
dc.subjectAirtightnesspt_PT
dc.subjectLeakagept_PT
dc.subjectPermeabilitypt_PT
dc.subjectRoller-shutterpt_PT
dc.subjectBlower doorpt_PT
dc.titleA contribution for the quantification of the influence of windows on the airtightness of Southern European buildingspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage185pt_PT
oaire.citation.startPage174pt_PT
oaire.citation.titleEnergy and Buildingspt_PT
oaire.citation.volume139pt_PT
rcaap.rightsclosedAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ENB - windows.pdf
Size:
755.5 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission