Repository logo
 
Publication

Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint

dc.contributor.authorCruz, Ana
dc.contributor.authorCunha, Beatriz
dc.contributor.authorPereira, Ana
dc.contributor.authorRodrigues, Maria
dc.contributor.authorSeabra, Eurico Augusto
dc.contributor.authorSilva, Luís
dc.contributor.authorColim, Ana
dc.contributor.authorViana, Rui
dc.date.accessioned2021-02-24T17:10:32Z
dc.date.available2021-02-24T17:10:32Z
dc.date.issued2020
dc.date.updated2021-02-24T16:11:15Z
dc.description.abstractIntroduction: Currently, there are several types of devices and techniques for the rehabilitation of the tibiotarsal joint. However, complete and effective rehabilitation still falls short of expectations, since the existing devices are not adaptable to the level of torque and the number of repetitions and sessions to be performed, as these depend on each patient and on the stage at which he is finds. Objetives: To improve a mechatronic device for the rehabilitation of the tibiotarsal joint, the Therapheet. Methods: This study presents a review of the tibiotarsal joint rehabilitation protocols, as well as the classification of devices used for this purpose. Thus, the purpose is to improve the Therapheet, developed at the Department of Mechanical Engineering of the University of Minho, obtaining a viable, functional and safe rehabilitation device, standing out from the rest on the market, since it allows the execution of the six rehabilitation exercises. Results: It was obtained a prototype of equipment for rehabilitation of the tibiotarsal joint was obtained, proposing changes for improvement according to the specificities and requirements for such a device, having been subjected to a series of preliminary tests to verify its functionality, performance and suitability. The equipment proved to be functional, in terms of executing the ankle rehabilitation movements, however, it still manifests some flaws in terms of the user's stability, sudden movements, and above all dysfunctions arising from excess mass that make up its structure and limitations pneumatic technology adopted. Conclusions: The control of the amplitude of the characteristic angles of the movements of the foot is still done manually, so it would be significant to implement an automated system that would allow the control of the range of amplitude, according to the patient's rehabilitation phase. One option would be the implementation of a new technology, such as the insertion of servomotors.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationCruz, A., Cunha, B., Pereira, A., Rodrigues, M., Seabra, E. A., Silva, L., Colim, A., & Viana, R. (2020). Study and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Joint. Millenium, 2(12), 13-23. DOI: 10.29352/mill0212.01.00324pt_PT
dc.identifier.doi10.29352/mill0212.01.00324pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.19/6629
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherInstituto Politécnico de Viseupt_PT
dc.relation.publisherversionhttps://revistas.rcaap.pt/millenium/article/view/19781pt_PT
dc.subjecttibiotarsal jointpt_PT
dc.subjectautomationpt_PT
dc.subjectdevicept_PT
dc.subjectrehabilitationpt_PT
dc.subjecttherapheetpt_PT
dc.titleStudy and Analysis of a New Device for the Rehabilitation of the Tibiotarsal Jointpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceViseupt_PT
oaire.citation.endPage23pt_PT
oaire.citation.issue12pt_PT
oaire.citation.startPage13pt_PT
oaire.citation.titleMilleniumpt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-art_STUDY AND ANALYSIS OF A NEW DEVICE_Ana_Cruz_gestão_EN.pdf
Size:
962.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.79 KB
Format:
Item-specific license agreed upon to submission
Description: